IEC Certifications
Mining : Ex ib I Mb
Gas : Ex ib IIC T4 Gb
Dust : Ex ib IIIC T110°C Db
–20°C≤Ta≤+55°C IEC 60079-0 (2017), IEC 60079-11 (2011)
ATEX Certifications
Mining : I M2 Ex ib I Mb
Gas : II 2G Ex ib IIC T4Gb
Dust : II 2D Ex ib IIIC T110°C Db
–20°C≤Ta≤+55°C
EN IEC 60079-0 (2018), EN 60079-11 (2012)
IP67 Dust-tight & Waterproof Protection
The IC-F3201DEX/F4201DEX provides rugged protection against dust and water that is equivalent to IP67. The IC-F3201DEX/F4201DEX can withstand 1m depth of water for 30 minutes and its dust-tight construction shuts out powder dust, sand and other objects.
IP67 Dust-tight & Waterproof Protection
The IC-F3201DEX/F4201DEX provides rugged protection against dust and water that is equivalent to IP67. The IC-F3201DEX/F4201DEX can withstand 1m depth of water for 30 minutes and its dust-tight construction shuts out powder dust, sand and other objects.
IDAS™ Digital Mode Operation
The IC-F3201DEX/F4201DEX provides can program NXDN™ Type-D single-site trunking and digital conventional as well as analog mode per channel. The following digital features are programmable.
• PTT ID (TX) • Individual/Group calls • Block decode
• Radio check (RX) • Stun/kill/revive (RX) • Call alert (RX)
• Remote monitor (RX) • Emergency (TX) • Digital voice scrambler (15-bit)
• Power ON/OFF status call (TX) • RAN (Radio Access Number)
• Voting scan for multi-site conventional operation
TX: Transmit, RX: Receive
Analogue Mode Compatible
The IC-F3201DEX/F4201DEX has built-in 5-Tone, 2-Tone, CTCSS and DTCS signaling capability for analogue mode group communication and selective calling. The lone worker and man down functions automatically send an emergency signal to assist in worker safety. The radio is perfect for use as an analogue transceiver ready for future digital migration.
Other Features
- 16 memory channels with channel announcement function
- MDC 1200 PTT ID and emergency transmission • DTMF autodial
- Three programmable buttons (including emergency red button)
- Low electrical resistivity body; Carrying case is not required
- 19.5–21 hours* operating time with BP-277EX (* 5: 5: 90 duty cycle with Power save.)
- Optional waterproof speaker-microphone, HM-203EX
ATEX mining protection and meaning
I |
M2 |
Ex |
ib |
I |
Mb |
Mb = Mining equipment protection level: High protection |
I = Explosion group, I = Methane |
||||||
ib = Intrinsic safety |
||||||
Ex = Explosion proof equipment |
||||||
M2 = Must be switched OFF in case of firedamp |
||||||
I = Group I, Mining |
ATEX gas protection and meaning
II |
2 |
G |
Ex |
ib |
IIC |
T4 |
Gb |
Gb = GAS equipment protection level: High protection |
T4 = Device surface temperature will not exceed 135°C |
||||||||
IIC = Protection in GAS group: Acetylene, Hydrogen |
||||||||
ib = Intrinsic safety |
||||||||
Ex = Explosion proof equipment |
||||||||
G = Gas, vapour and mist |
||||||||
2 = High level protection for use in Zone 1 (gas) |
||||||||
II = Group II, other (non-mining) areas |
ATEX dust protection and meaning
II |
2 |
D |
Ex |
ib |
IIIC |
T110°C |
Db |
Db = Dust equipment protection level: High protection |
T110°C = Maximum temperature of device surface |
||||||||
IIIC = Dust group: Conductive dust (R≤103 Ωm) |
||||||||
ib = Intrinsic safety |
||||||||
Ex = Explosion proof equipment |
||||||||
D = Dust |
||||||||
2 = High level protection for use in Zone 21 (dust) |
||||||||
II = Group II, other (non-mining) areas |
* Please ask your dealer to ensure the ATEX and IECEx ratings are acceptable for the intended place of use.
GENERAL
IC-F3201DEX | IC-F4201DEX | ||
---|---|---|---|
Frequency coverage | 136–174 MHz | 400–470 MHz | |
Number of channels | 16 channels | ||
Type of emission | 11K0F3E, 8K50F3E, 4K00F1E/F1D | ||
Power supply requirement | 7.4 V DC nominal | ||
Current drain (approximate) | Tx (High) | 550 mA | |
Rx (Max./Standby) | 300 mA (Internal SP)/110 mA (Digital mode) | ||
Antenna impedance | 50Ω | ||
Operating temperature range | –20°C to +55°C; –4°F to +131°F | ||
Dimensions (W×H×D) (Projections not included) |
63 × 144 × 50 mm; 2.48 × 5.67 × 1.97 in (With BP-277EX) |
||
Weight (approx.) | 258 g; 9.1 oz (Radio only) 466 g; 1.03 lb (With MB-94EX, BP-277EX & FA-SC55V) |
250 g; 8.8 oz (Radio only) 460 g; 1.01 lb (With MB-94EX, BP-277EX & FA-SC57U) |
Transmitter
IC-F3201DEX | IC-F4201DEX | ||
---|---|---|---|
Output power (at 7.4 V DC) | 1 W, 0.8 W, 0.6 W (Hi, L2, L1) | ||
Max. permissible deviation | ±2.5 kHz (Narrow) | ||
Frequency stability | ±1.0ppm | ||
Spurious emissions | 66 dB min. | ||
FM Hum and Noise | 46 dB typ. (Narrow) | 40 dB typ. (Narrow) | |
Audio harmonic distortion | 1.5% typ. (Narrow @ AF 1 kHz 40% deviation) | ||
FSK error | 2.0% typ. (Digital) | 1.5% typ. (Digital) | |
Ext. microphone connector | 14-pin multi-connector/2.2 kΩ |
RECEIVER
IC-F3201DEX | IC-F4201DEX | ||
---|---|---|---|
Sensitivity | Analog (12 dB SINAD) | 0.24 μV typ. | 0.22 μV typ. |
Digital (5% BER) | –8 dBμV emf typ. | ||
66/57 dB typ. (Narrow/Digital | |||
Adjacent channel selectivity | 70/62 dB typ. (Narrow/Digital) | 6dB6/57 dB typ. (Narrow/Digital) | |
Spurious response | 85 dB typ. (Narrow), 87 dBμV emf typ. (Digital) |
75 dB typ. (Narrow), 79 dBμV emf typ. (Digital) |
|
Intermodulation | 75/67 dB typ. (Narrow/Digital) | 74/73 dB typ. (Narrow/Digital) | |
Hum and noise | 43 dB typ. (Narrow) | 37 dB typ. (Narrow) | |
Audio output power | 400 mW typ. (at 5% distortion with 32 Ω load) | ||
External speaker connector | 14-pin multi-connector/32 Ω |
Measurements made in accordance with TIA-603, EN 300-086, EN 301-166.
All stated specifications are subject to change without notice or obligation.
Applicable U.S. Military Specifications & IP Rating Standard MIL 8
Standard |
MIL-810 G | |
---|---|---|
Method | Procedure | |
Low Pressure | 500.5 | I, II |
High Temperature | 501.5 | I, II |
Low Temperature | 502.5 | I, II |
Temperature Shock | 503.5 | I-C |
Solar Radiation | 505.5 | I |
Rain Blowing/Drip | 506.5 | I, III |
Humidity | 507.5 | II |
Salt Fog | 509.5 | – |
Dust Blowing | 510.5 | I |
Immersion | 512.5 | I |
Vibration | 514.6 | I |
Shock | 516.6 | I, IV |
Also meets equivalent MIL-STD-810-C, -D -E and -F.
Ingress Protection Standard | |
---|---|
Dust & Water | IP67 (Dust-tight and waterproof) |
Supplied accessories: (May differ according to version)
- • Battery pack, BP-277EX
- • Belt clip, MB-94EX
- • Antenna
- • Battery charger, BC-212EX
- • AC adapter, BC-123S
MICROPHONES
BATTERIES
CHARGERS
Catalogs / Brochures
Brochures Name | Size |
---|---|
IC-F3201DEX/IC-F4201DEX | 397KB |
Professional Radios | 12.11MB |
IDAS™ Solutions | 2.43MB |
Instruction Manual / Guides
Name | Model Name | Note |
---|---|---|
PRECAUTIONS | IC-F3200DEX/IC-F4200DEX | |
INSTRUCTIONS | IC-F3200DEX/IC-F4200DEX |